Panasonic AC Fault Troubleshooting / Inverter type







Panasonic Inverter (Untuk Single CSE, CSXE, dan multi CSME)

H11> Communication Failure (Faulty Wiring or other problem with ID to OD communication)
H12> ID/OD Compatibility Problem (Over or Under indexed multi system)
H14> Indoor Air Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H15> Compressor Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H16> Current Transformer Problem (Power Transistor Module or Outdoor PCB Faulty. Very Low Gas)
H19> Indoor Fan Motor Locked (Fan Motor of Indoor PCB Failure)
H21> Float Switch Operated (Check Drainage)
H23> Indoor Pipe Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H27> Outdoor Air Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H28> Outdoor Pipe Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H30> Outdoor Discharge Sensor 1 Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H32> Outdoor Discharge Sensor 2 Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H33> Incorrect Connection Voltage (Indoor or Outdoor Voltage Incorrect/Faulty Wiring)
H34> Outdoor Heat Sink Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H36> Outdoor Gas Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H37> Outdoor Liquid Sensor Faulty (Sensor Disconnected, Faulty or Contacts Dirty)
H39> Abnormal Indoor Operation (Incorrect Piping or Expansion Valve Problem)
H41> Abnormal Wiring or Piping (Wiring or Piping Crossed on a Twin System)
H97> Outdoor Fan Failure (Outdoor Fan Motor or PCB Failure)
H98> Indoor Coil Overheat (Heat Mode) (Dirty Filters or Indoor Coil. Very High Room Temperature)
H99> Indoor Coil De-Ice (Cool Mode) (Dirty Filters or Indoor Coil. Low Gas Charge or Low Ambient Temp)
F11> Reversing Valve Failure (Faulty Reversing Valve, Coil or Outdoor PCB)
F17> Standby Units Freezing (Multi Only. Expansion Valve Leakage)
F90> PFC Failure (Problem with Inverter or Compressor)
F91> Refrigeration Cycle Problem (Low Gas or Blockage)
F93> Compressor Abnormal Revolution (Compressor Running Incorrectly)
F95> Outdoor Coil Overheat (Cool Mode) (Dirty Condensor Coil, low gas or blockage)
F96> IPM or Compressor Overheating (Excess or Low Gas Charge or dirty heat exchanger)
F97> High Discharge/Compressor Temp (Low Gas Charge or Failed Compressor)
F98> Overcurrent Protection (Outdoor Heat Exchanger Problem. Excess Gas)
F99> DC Overcurrent Protection (Outdoor PC, Power Transistor or Compressor Failure)
 